It is a fast steam producer for using plants like textile, hospitals, hotels, laundry services, kitchen, dry cleaning, food, agriculture, chemistry, paint, medicine, leather, conserve, dairy farm, drink bottle, concrete industries. It cracks for different productions with 14 free capacities between 70 kg/h – 2000 kg/h. It takes little room; boiler standby losses have minimum level while heat efficiency level rising up maximum thanks to excellent heat insulation. It works full capacity within the shortest possible time and supplies the necessity of plant with dry steam.

Itimat steam generators work free of problems many years and it has low operating costs for life. Operating and servicing are easy for these generators. Hard water doesn’t affect these generators. It has hand hole for clean water side.

Itimat Jet steam generators get under control with the help of flue gas, impulses takes from steam and digital thermostats. Work pressure restricted by presosts. Water level blocked specific limit by level electrodes, magnetic and mechanic indicators. The system has weighted and elastic safety valves for mechanic safety control.

THE OPERATING AND SAFETY ELEMENTS ON THE VAPOR GENERATOR BEING OF THE CLASS A AND IN COMPLIANCE WITH INTERNATIONAL STANDARDS, THEY ARE EQUIPPED WITH ELEGANT PRODUCTS OF THE LEADING COMPANIES IN THE WORLD.

 

JET STEAM GENERATORS ACCESSORIES

OPERATING HARDWARE

  • Burner ( liquid – gas fuel )
  • Condenser tank and armatures
  • Feed pomp and armatures
  • Full automatic water moderate apparatus and armatures
  • Water level control regulator
  • Magnetic level indicator
  • Operating presost
  • Digital control panel

 

SAFETY HARDWARE

  • Safety valves
  • Safety presosts
  • Steam thermostat
  • Flue gas thermostat
  • Minimum water level electrodes
  • Critical situation switch and lighted alarm system
  • Bow down valves

OPTIONAL ECONOMY 0EQUIPMENT

  • Economiser
  • Rotational burner
  • Burner controlled by inverter
  • Control panel with PLC
  • Pneumatic main steam valve

 



 
 
   
TYPE
JBU-100
JBU-200
JBU-300
JBU-500
JBU-600
JBU-750
JBU-1000
JBU-1250
JBU-1500
JBU-2000
JBU-2500
CAPACITY
HEAT
kcal/h
60.000
120.000
180.000
300.000
360.000
450.000
600.000
750.000
900.000
1.200.000
1.500.000
kW
70
139
209
349
419
523
698
872
1047
1395
1744
STEAM
kg/h
100
200
300
500
600
750
1000
1250
6500
2000
2500
LENGTH
mm
1700
2000
2400
2800
3000
3100
3500
3600
3700
4200
4700
WIDTH
mm
1000
1250
1300
1500
1600
1700
1700
1700
1700
1900
2100
HEIGHT
mm
1700
1700
1800
2200
2300
2600
2760
2085
3000
3200
3300
WATER VOLUME
lt
75
150
260
500
550
700
900
1300
1400
1510
1800
FLUE SIZE
mm
200
200
250
300
350
350
400
400
450
500
550
STEAM OUTPUT
nmm
20
25
32
40
50
50
65
65
80
80
100
APPROXIMATE WEIGHT
kg
800
1150
1315
1890
2200
3000
3325
3600
4250
5300
6500
PRESSURE
mbar
1
1
1,5
2,5
3
4
4
4
5
5
5
FUEL CONSUMPTION
DIESEL
Kg/h
7
13
20
33
40
50
67
84
100
134
167
FUEL-OILl
Kg/h
7
14
21
35
42
53
70
88
106
141
176
NATURAL GAS
Nm3/h
8
16
24
40
48
60
80
100
120
160
200
LPG
Kg/h
6
18
17,5
29,5
35,5
44
59
74
88
118
147
* We have the right to change the dimensions according to the technological developments.
* Please call us if you cannot find any capacity value in this table.
* Technical data valid for 6 bar operating pressure.
 
   
 
 